these parameters in addition to the normal air
dive parameters (discussed in the preceding
section).
This section will examine the general
parameters for EAN dives monitored by Nemo
Wide and the differences in how the data are
displayed.
WARNING
It is essential to correctly set the oxygen
percentage in the mix to ensure correct
readouts of:
no decompression time remaining;
decompression stop times;
alarm on exceeding the maximum
permitted PPO
.
WARNING
Before the dive, make sure you have
correctly set up all the EAN dive parameters:
percentage of oxygen in the mix and limit
for the partial pressure of oxygen, which
together determine the maximum depth of
the dive.
WARNING
The use of oxygen rich mixes exposes
the diver to different hazards from those
associated with compressed air. The
diver should be aware of these risks and
understand how to avoid them.
WARNING
Nemo Wide should only be used for diving
with oxygen rich mixes (EAN) by divers
who have the necessary certification. Lack
of appropriate diver training may result in
possibly serious injury.
WARNING
The user is advised to carefully read the
section on compressed air diving before
reading the section on EAN dives.
MONITORING OF THE GENERAL
DIVE PARAMETERS
OXYGEN PARTIAL PRESSURE
When the diver reaches a depth at which the
PPO
2
exceeds the maximum limit entered in
the corresponding parameter, (from 1.2 to 1.6
ATM), Nemo Wide triggers an alarm condition
signaled by:
blinking depth indicator;
audible alarm.
The alarm persists until the diver ascends
enough for the PPO
2
to return within the
programmed limit.
WARNING
When the max PPO
2
alarm goes off, ascend
immediately until the alarm turns off.
EFFECTS ON CENTRAL NERVOUS SYSTEM
Oxygen toxicity exposure is monitored by means
of a CNS (Central System Calculation), based
on currently accepted recommendations for
exposure limits.
This toxicity is expressed as a percentage
value which ranges from 0% to 100%. The
percentage CNS value is shown on the display.
An alarm is triggered when it exceeds 75%,
signaled by blinking of the value.
PREDIVE  EAN
This operating mode remains active until the
diver goes below 1.2 meters (4 ft).
The following details are displayed (Fig. 22):
type of dive (EAN);
units of measurement (m-°C or ft-°F);
type of water (Salt, Fresh);
altitude program (if enabled) and level;
personal correction factor (if enabled) and
level;
icon for %O
2
.
Fig. 22
NOTE
If Predive Mode persists for more than 10
minutes without any button being pressed,
Nemo Wide will revert to Time mode.
NOTE
Before every dive, it is advisable to
enter Set Dive mode and check all
the parameter settings and the EAN
parameters in particular.
WARNING
We advise that when diving you always put
Nemo Wide into Predive mode.
Always check that the dive computer is
switched on early in your dive.
DIVE  EAN:
“NODECOMPRESSION” DIVE
When the diver descends below 1.2 meters (4
ft) Nemo Wide automatically switches to Dive
Mode and starts displaying the dive data.
If this mode persists for more than 20 seconds,
Nemo Wide will begin recording the dive
details in the Log Book memory.
The following details are displayed (Fig. 23):
current depth (in “m” or “ft”);
no decompression time remaining,
expressed in minutes;
“no deco” icon;
icons for the altitude program and personal
correction factor (if enabled).
the % O
2
;
the % CNS.
Fig. 23
NOTE
The procedure for scrolling the items on
the display is identical to that described in
the section on diving with compressed air.
NOTE
The functions of the buttons are identical
to those described in the section on diving
with compressed air.
In this mode the buttons function as follows:
<+> button:
Press this button to display the maximum
depth reached. Press it again to remove the
maximum depth.
Hold down the button for 2 seconds to
activate the display backlight.
<-> button:
by pressing this button you can choose to view
on the display bar:
the % O
2
;
the % CNS.
Or
the temperature (in °C or in °F);
the duration of the dive so far (dive time) in
digits.
<ENTER> button:
hold down this button to display the dive
settings with the same window as the Predive
mode.
<ESC> button:
When the <ESC> button is pressed during
the dive, Nemo Wide will temporarily display
the estimated deep stop required. The data
displayed during the ascent may vary as a
result of the diver’s behavior. Divers should
check this data during the ascent for more
precise information on the estimated stop.
DIVE 
EAN “DECOMPRESSION STOP” DIVE
The data displayed for decompression-stop
diving with EAN are as follows (Fig. 24):
“deco” icon;
current depth (in “m” or “ft”);
depth of deepest decompression stop
(in “m” or “ft”);
duration of the deepest decompression stop;
icons for the altitude program and personal
correction factor (if enabled).