In this mode the buttons function as follows:
<+> button:
Press this button to display the maximum
depth reached. Press it again to remove the
maximum depth.
Hold down the button for 2 seconds to
activate the display backlight.
<-> button:
by pressing this button you can choose to view
on the display bar:
total time to surface;
the % CNS.
Or
the temperature (in °C or in °F);
the duration of the dive so far (dive time) in
digits.
<ENTER> button:
temporarily displays (for 10 seconds) the
dive parameter settings, just as they appear
in Predive Mode.
<ESC> button:
When the <ESC> button is pressed during
the dive, Nemo Wide will temporarily display
the estimated deep stop required. The data
displayed during the ascent may vary as a
result of the diver’s behavior. Divers should
check this data during the ascent for more
precise information on the estimated stop.
WARNING
To fully understand how to perform
decompression with EAN, the user should
also carefully read the corresponding
section for compressed-air deco stop dives.
NOTE
If you have completed an EAN dive and
wish to do a repetitive dive with air, set the
computer for “EAN” with O
2
at 21%. By so
doing, the calculation of the %CNS will
remain active.
SURFACING  EAN
When the measured depth is less than 1 m
(3 ft), Nemo Wide considers the dive to be
suspended (“Surfacing”) and halts the dive
timer. If the diver does not return below 1.5 m
(5 ft) within the next 3 minutes, Nemo Wide
considers the dive to be finished and records its
data in the log book memory. If the diver does
re-descend within 3 minutes, the dive continues
and the dive timer resumes from where it left
off.
Data displayed in Surface mode (Fig. 25):
duration of the dive;
maximum depth;
icons for any mistakes made during the
dive(omitted stop, uncontrolled ascent)
display of % CNS
FIG. 25
SURFACE MODE  EAN
The data displayed in Surface - EAN mode
is the same as that for Surface - AIR mode,
except for the addition of the % CNS value
(Fig. 26).
FIG. 26
DIVE  BOTTOM TIME GAUGE
In this mode Nemo Wide functions as an
electronic timer and depth gauge, but does not
perform any calculations for no-deco limits or
for deco-stop times.
Responsibility for planning the no-
decompression limits or an adequate
decompression therefore lies entirely with the
user.
The details displayed in Predive and Surfacing
mode are the same as those already described
for air or EAN dives.
The data shown in Dive mode however are the
following (Fig. 27):
dive time,
current depth;
ascent rate;
temperature (in °C or in °F);
the primary time.
In this mode the buttons function as follows:
<+> button:
Press this button to display the maximum
depth reached. Press it again to remove the
maximum depth.
Hold down the button for 2 seconds to
activate the display backlight.
<-> button:
this button is not enabled in this mode.
<ENTER> button:
temporarily displays (for 10 seconds) the
dive parameter settings, just as they appear
in Predive Mode.
<ESC> button:
this button is not enabled in this mode.
FIG. 27
WARNING
We advise that when diving you always put
Nemo Wide into Predive mode. Always
check that the dive computer is switched
on early in your dive.
NOTE
After a dive in “BT” mode, the transition to
AIR” or “EAN” mode will be disabled for
24 hours. (This lockout can be disabled by
clearing the residual nitrogen memory in
Set Dive - Data mode).
WARNING
This option is intended only for highly
experienced divers. Users who clear the
residual nitrogen memory cannot then
use the instrument for repetitive dives.
After this operation, do not dive with Nemo
Wide if you have already dived within the
previous 24 hours.
SURFACE MODE  BOTTOM TIME
The desaturation time and the delay before
flying or traveling to high altitudes are
displayed in the same way as for Air or EAN
dives.
BOTTOM TIME WITH BEHAVIOR
ERROR
The following errors can occur during an air or
EAN dive:
Uncontrolled ascent
Omitted deco stop
In this case, Nemo Wide will inhibit the
Dive - AIR and Dive - EAN modes for 24 hours,
allowing operation in BOTTOM TIME mode only,
and will continue to display the underwater
behavior error in question.
The corresponding error icons are displayed in
Dive, Time and Logbook mode.
Vue de la page 9