Mares NEMO AIR Guide de l'utilisateur Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
5
SET DIVE  DATA
SET DIVE  DATA  FRESH / SALT
WARNING
Before diving, make sure you have
correctly set the units of measurement. An
incorrect setting may give rise to confusion
during the dive, and hence to underwater
behavior errors.
To ensure maximum accuracy, you need to set
Nemo Wide for either fresh water (“Fresh”)
or seawater (“Salt”) as appropriate. Check
this setting often, especially if you use the
instrument in a variety of environments (lake,
sea, swimming pool).
Use the <+> or <-> buttons to adjust the values.
Press the <ENTER> button to save the changes
made and move to the next selection.
The <ESC> button exits to the previous set.
SET DIVE  DATA  °C METERS / °F FEET
You can select which units of measure you
want to use: metric (°C and m) or Imperial
(°F and ft).
Use the <+> or <-> buttons to adjust the values.
Press the <ENTER> button to save the changes
made and move to the next selection.
The <ESC> button exits to the previous set.
SET DIVE  DATA  DEL TISSUE
WARNING
This option is intended only for highly
experienced divers. Users who clear the
residual nitrogen memory cannot use the
instrument for repetitive dives. After this
operation, do not dive with Nemo Wide if
you have already dived within the previous
24 hours.
This item is used for clearing the residual
nitrogen memory of the tissue compartments.
In Set Dive - Data mode, scroll until the
blinking “DELETE” message appears.
Press <ENTER> to call up the confirmation
option, which will show a blinking “NO”
message. Use the <+> or <-> buttons to change
to “OK”.
Then, once the “OK” message is displayed,
press <ENTER> to clear the residual nitrogen
in the tissue compartments.
If you do not wish to clear the residual nitrogen
memory in the tissue compartments, press
<ENTER> when “NO” is displayed.
The <ESC> button exits to the previous set.
Press the <ENTER> button after the last item
to return to the Set dive - Data menu.
Now we can move to the Set dive - Mode using
the <+> and <-> keys.
SET DIVE  MODE
Set Dive - Mode is used for setting the general
parameters for the planned type of dive.
Press ENTER to access this menu.
Here you can select the dive you have planned
and adjust the corresponding parameters
accordingly. The last operational mode will
appear selected from among:
AIR
EAN
BOTTOM TIME
Use the <+> and <-> keys to choose the dive
type desired.
NOTE
If you have completed an EAN dive and
wish to do a repetitive dive with air, set the
computer for “EAN” with O
2
at 21%. By so
doing, the calculation of the % CNS will
remain active.
AIR
This section covers dives using compressed
air as the breathing mix. When you see the
word AIR, in Set dive - Mode, press the ENTER
button. First of all, you can adjust the altitude.
SET  AIR  ALTITUDE
Altitude programs:
P0
(0-700 m)(0-2296 ft)
P1
(700-1500 m)(2296-4921 ft)
P2
(1500-2400 m)(4921-7874 ft)
P3
(2400-3700 m)(7874-12139 ft)
When this item is accessed, it displays an
indication of the current altitude program (P0,
P1, P2, P3) (Fig. 5). Use the <+> or <-> buttons
to enter the desired value. Press <ENTER>
to save the changes and advance to the next
setting.
Fig. 5
NOTE
This setting cannot be changed during the
dive. Therefore, carefully check all settings
before going underwater.
WARNING
Do not dive in mountain lakes without
having first checked that the appropriate
altitude program is selected.
SET  AIR  PERSONAL CORRECTION FACTOR
Nemo Wide includes a personal correction factor,
which you can set for added safety, to make the
algorithm more conservative. The correction
factor should be used by inexperienced divers,
for strenuous dives or when diving after a
prolonged period of inactivity.
The PF 0 program introduces no additional
margin of safety.
This icon, which appears during the dive,
indicates whether a personal correction factor
is enabled, and if so, its level.
The current personal safety factor program
(PF0, PF1, PF2) is displayed when you turn on
the computer (Fig. 6).
Fig. 6
Use the <+> and <-> keys to set the desired
value.
Press <ENTER> to save your selection and
move to the next set.
SET  AIR  FAST ASC
WARNING
A rapid ascent increases the risk of
decompression sickness.
This function enables or disables the “Stop”
function in case of uncontrolled ascent, to
prevent the dive computer from locking
out after a rapid ascent. The feature can be
particularly useful for instructors who need to
practice emergency ascents.
It displays the current setting (“ON” or “OFF”)
when activated (Fig. 7).
Fig. 7
Use the <+> or <-> buttons to change the
setting.
Press <ENTER> to save the changes and
advance to the next setting.
WARNING
This function is intended only for highly
experienced divers, who take full
responsibility for the consequences of
disabling the “Stop” on uncontrolled
ascent.
SET  AIR  AL BEEP
This function enables or disables the audible
alarms.
When the computer is turned on, it displays
the current setting (“ON” or “OFF”).
Use the <+> or <-> buttons to change the
setting.
Press <ENTER> to save and return to
Set – Mode.
The <ESC> button returns you to the main
menu.
Vue de la page 4
1 2 3 4 5 6 7 8 9 10 ... 13 14

Commentaires sur ces manuels

Pas de commentaire